Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 12.602
Filtrar
1.
Int Ophthalmol ; 44(1): 169, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38587565

RESUMO

PURPOSE: To evaluate long-term postoperative corneal changes after phacoemulsification cataract surgery. METHODS: Twenty patients who participated in a previous study regarding corneal endothelial changes after phacoemulsification cataract surgery were examined after 7 years. The patients were divided in three groups based on their initial increase in central corneal thickness day one after the surgery: < 5% increase, 6-20% increase and ≥ 20% increase. The primary outcome measures were corneal endothelial cell loss (ECL), endothelial cell count (ECC) and endothelial morphology. RESULTS: After 7 years, a difference in cell loss between the groups was observed, except for groups 1 and 2. Endothelial cell count (ECC) differed significantly between groups 1 and 3 at 3 months. At 7 years, there was no difference in ECC between the three groups. Cell loss was found exclusively in group 1 between 3 months and 7 years. Endothelial cell morphology showed a converging pattern between 3 months and 7 years. CONCLUSION: After phacoemulsification cataract surgery, long-term ECC and morphology appear to converge towards a comparable steady state regardless of initial corneal swelling and endothelial cell loss.


Assuntos
Extração de Catarata , Catarata , Facoemulsificação , Humanos , Facoemulsificação/efeitos adversos , Endotélio Corneano , Córnea
2.
PLoS One ; 19(4): e0300148, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38593138

RESUMO

PURPOSE: To assess the association between vitreous hyper-reflective dots (VHD) and the macular thickness changes following uneventful phacoemulsification. METHODS: In this prospective cohort study optical coherence tomography (OCT) examinations were performed preoperatively and 1 week, 1 month and 3 months postoperatively in patients undergoing cataract surgery. OCT images were analyzed for retinal central subfield thickness (CST) and preretinal VHDs. Surgeries were recorded for the assessment of lens fragments in the space of Berger. RESULTS: 111 eyes of 97 patient were enrolled of whom 69 (62.2%) were female. VHDs were seen in 25 eyes (22.5%) at week 1; in 21 eyes (18.9%) at month 1 and in 3 eyes (2.7%) at month 3. In all eyes with VHDs retro-capsular lens fragments were visible immediately after phacoemulsification. The number of VHDs significantly decreased over the postoperative period. There was a moderate correlation between the number of VHDs and CST at 1 month (r = 0.426, p<0.001). In eyes with VHD the CST averaged 238.8±17.6 µm (214-266) at 1 week; 276.1±63.5 µm (231-481) at 1 month and 285.1±122.3 µm (227-785) at 3 months. In eyes with no detectable VHDs CST averaged 235.9±23.3 µm (192-311) at 1 week; 240.1±21.6 µm (200-288) at 1 month and 242.2±21.3 µm (205-289) at 3 months. Although the differences among the assessment points were relatively low, there was a significant difference in general (p<0.001, Friedman test). CONCLUSION: In conclusion, VHDs seem to cause macular thickening throughout the postoperative course. The origin of VHDs is still unknown; however, they presumably represent lens fragments that provoke subclinical inflammation.


Assuntos
Extração de Catarata , Catarata , Edema Macular , Facoemulsificação , Humanos , Feminino , Masculino , Edema Macular/etiologia , Estudos Prospectivos , Extração de Catarata/efeitos adversos , Retina , Facoemulsificação/efeitos adversos , Tomografia de Coerência Óptica/métodos , Catarata/diagnóstico por imagem , Catarata/complicações
3.
Zhonghua Yi Xue Za Zhi ; 104(16): 1391-1396, 2024 Apr 23.
Artigo em Chinês | MEDLINE | ID: mdl-38644289

RESUMO

Objective: To explore the effects of different types of intraocular lens (IOL) implantation on patient's visual quality and function after phacoemulsification. Methods: The clinical data of patients with monocular cataract who underwent phacoemulsification in the Department of Ophthalmology, People's Hospital Affiliated to Shandong First Medical University between December 2021 and May 2023 were retrospectively analyzed. According to the types of IOL, the patients were divided into monofocal group, bifocal group and depth of focus extension group. Three months later, uncorrected distance visual acuity (UCDVA), best corrected distance visual acuity (BCDVA), uncorrected intermediate visual acuity (UCIVA), best corrected intermediate visual acuity (BCIVA), uncorrected near visual acuity (UCNVA) and best corrected near visual acuity (BCNVA) were detected. Contrast sensitivity and total wavefront aberration were measured by visual function analyzer. Satisfaction with visual quality was evaluated by hospital-made satisfaction questionnaire. Results: A total of 92 patients were included, with 31 males and 61 females, and their age was (61.8±5.2) years. There were 43, 28 and 21 cases in monofocal group, bifocal group and depth of focus extension group, respectively. No statistically significant difference was found in clinical baseline data among the three groups. UCIVA, UCDVA, BCIVA and BCDVA in depth of focus extension group were 1.01±0.13, 0.92±0.18, 1.21±0.19 and 1.20±0.23, respectively, which were higher than those in monofocal group (0.62±0.12, 0.74±0.13, 1.02±0.17, 1.07±0.19, respectively) and bifocal group (0.67±0.15, 0.78±0.14, 1.01±0.16, 1.01±0.18, respectively), while absolute value of spherical equivalent [(-0.42±0.07) D] was lower than that in the other two groups [ (-0.49±0.05) D and (-0.45±0.08) D] (both P<0.05). UCNVA and BCNVA in bifocal group were 0.91±0.18 and 1.25±0.18, which were higher than those in depth of focus extension group (0.63±0.24 and 1.19±0.17) (both P<0.05). There were no significant differences in contrast sensitivity among the three groups under day vision or between monofocal group and bifocal group under night vision (all P>0.05), but the contrast sensitivity was higher in depth of focus extension group under night vision (3.0, 6.0, 12.0 c/d) than other two groups (all P<0.05). The score of ocular discomfort was the highest in bifocal group, followed by depth of focus extension group and monofocal group (both P<0.05). The score of visual interference in bifocal group was lower than that in monofocal group and depth of focus extension group (both P<0.05). The scores of subjective feeling in bifocal group and depth of focus extension group were higher than that in monofocal group (both P<0.05). The reading score was the highest in bifocal group, followed by depth of focus extension group and monofocal group (both P<0.05). There was no significant difference in total low-order aberration among the three groups (P=0.472). The total aberration and higher-order aberration [(0.74±0.35) µm and (0.41±0.12) µm] were the highest in monofocal group, followed by bifocal group [(0.61±0.21) µm and (0.22±0.09) µm] and depth of focus extension group [(0.46±0.13) µm and (0.06±0.09) µm] (all P<0.05). Conclusions: IOL implantation with depth of focus extension can enhance visual range, night vision and contrast sensitivity, and thus effectively improve postoperative visual quality and function in cataract patients. The bifocal IOL can better improve the patient's UCNVA and BCNVA, resulting in high satisfaction with visual quality.


Assuntos
Catarata , Implante de Lente Intraocular , Lentes Intraoculares , Facoemulsificação , Acuidade Visual , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidades de Contraste , Satisfação do Paciente , Inquéritos e Questionários
4.
BMC Ophthalmol ; 24(1): 172, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627651

RESUMO

PURPOSE: To assess the efficacy and safety of various intraocular lenses (IOLs), including standard monofocal, bifocal, trifocal, extended depth of focus (EDOF), and enhanced monofocal IOLs, post-cataract surgery through a network meta-analysis. METHODS: A systematic search of PubMed, Cochrane Library, and Web of Science was conducted to identify relevant studies from the past 5 years. Parameters such as binocular visual acuities, spectacle independence, contrast sensitivity (CS), and optical quality were used to evaluate efficacy and safety. Data from the selected studies were analyzed using Review Manager 5.4 and STATA 17.0 software. RESULTS: Twenty-eight Randomized Controlled Trials (RCTs) comprising 2465 subjects were included. Trifocal IOLs exhibited superior uncorrected near visual acuity (UNVA) compared to monofocal IOLs (MD: -0.35; 95% CI: -0.48, -0.22). Both trifocal (AcrySof IQ PanOptix IOLs group MD: -0.13; 95% CI: -0.21, -0.06) and EDOF IOLs (MD: -0.13; 95% CI: -0.17, -0.09) showed better uncorrected intermediate visual acuity (UIVA) than monofocal IOLs. Trifocal IOLs ranked highest in spectacle independence at various distances (AT LISAtri 839MP group: SUCRA 97.5% for distance, 80.7% for intermediate; AcrySof IQ PanOptix group: SUCRA 83.0% for near). CONCLUSIONS: For cataract patients who want to treat presbyopia, trifocal IOLs demonstrated better visual acuity and spectacle independence at near distances. Different types of trifocal IOL characteristics differ. EDOF and enhanced monofocal IOLs have improved visual quality at intermediate distances.Therefore, It is very important to select the appropriate IOLs based on the lens characteristics and patient needs.


Assuntos
Catarata , Lentes Intraoculares , Facoemulsificação , Presbiopia , Humanos , Implante de Lente Intraocular , Presbiopia/cirurgia , Refração Ocular , Satisfação do Paciente , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto
5.
Transl Vis Sci Technol ; 13(4): 11, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38578634

RESUMO

Background: The purpose of this study was to explore the protective effect of a shape memory polymeric shield on corneal endothelium during phacoemulsification in rabbits. Methods: Poly-(glycerol dodecanedioate) (PGD) with a transition temperature of 24.416°C was prepared to make a shape memory shield with a thickness of 100 µm, an arc length of 14 mm, and a radius of curvature of 8.8 mm. In the control group, a phaco-tip with bevel-down was used to simulate injury to the corneal endothelium by phacoemulsification in rabbits. In the experimental group, the pre-cooled and curled shape memory shield was injected into and removed from the anterior chamber before and after phaco-power release. Anterior segment optical coherence tomography (AS-OCT), confocal microscope, trypan blue/alizarin red staining, and scanning electron microscope were performed to measure endothelial damage after surgery. Results: One day postoperatively, the lost cell ratio of the control group and the experimental group were 28.08 ± 5.21% and 3.50 ± 1.43%, respectively (P < 0.0001), the damaged cell ratios were 11.83 ± 2.30% and 2.55 ± 0.52%, respectively (P < 0.0001), and the central corneal thicknesses (CCT) were 406.75 ± 16.74 µm and 340. 5 ±13.48 µm, respectively (P < 0.0001). Seven days postoperatively, the endothelial cell density (ECD) of the control group and the experimental group were 1674 ± 285/mm2 and 2561 ± 554/mm2, respectively (P < 0.05). The above differences were all statistically significant. Conclusions: This PGD based shape memory shield has a protective effect on corneal endothelium during phacoemulsification. It reduces postoperative corneal edema and ECD decrease in the short term after surgery. Translational Relevance: The shape memory PGD "shield" in this study may have a use in certain human patients with vulnerable corneas of low endothelial cell count or shallow anterior chambers.


Assuntos
Endotélio Corneano , Facoemulsificação , Animais , Humanos , Coelhos , Facoemulsificação/efeitos adversos , Facoemulsificação/métodos , Córnea , Câmara Anterior
6.
J Refract Surg ; 40(4): e208-e217, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38593256

RESUMO

PURPOSE: To evaluate spherical intraocular lens (IOL) implantation for cataracts in keratoconic eyes followed by optional refractive toric lens exchange to improve uncorrected visual acuity. METHODS: This retrospective study evaluated cataract surgery outcomes in keratoconic eyes. Eyes treated with a spherical IOL targeted for -2.00 diopters (D) either achieved acceptable manifest refraction and desired exchange with a toric IOL (Group 1); achieved satisfactory manifest refraction and chose to use spectacles or contact lenses (Group 2); or did not achieve acceptable refraction and used contact lenses (Group 3). Group 4 had single-stage toric IOL implantation with plano target. Corrected and uncorrected distance visual acuity (CDVA and UDVA) and keratometry were analyzed. RESULTS: Groups 1 to 4 had 18, 23, 18, and 26 eyes, respectively. A staged toric exchange resulted in significantly better (P = .02) UDVA (mean: 0.15 logMAR; 20/25 Snellen) than initial toric IOL implantation (0.24 logMAR; 20/30 Snellen). All toric IOL exchange eyes achieved 20/30 or better CDVA and 94% had 20/40 or better UDVA. Mean manifest cylinder significantly decreased from 3.39 D before lens exchange to 1.10 D postoperatively. CONCLUSIONS: Initial implantation of a spherical IOL in keratoconic eyes allows basing toric calculations on the manifest refraction, which may be more reliable than keratometry measurements in keratoconic eyes. UDVA after staged toric IOL exchange was significantly better than after initial toric IOL implantation. Importantly, by staging use of toric lenses, the authors avoided cases where patients required a rigid contact lens after a toric IOL was implanted. [J Refract Surg. 2024;40(4):e207-e217.].


Assuntos
Astigmatismo , Catarata , Ceratocone , Lentes Intraoculares , Facoemulsificação , Humanos , Ceratocone/complicações , Ceratocone/cirurgia , Estudos Retrospectivos , Facoemulsificação/métodos , Resultado do Tratamento , Astigmatismo/cirurgia , Refração Ocular , Catarata/complicações
7.
J Refract Surg ; 40(4): e270-e277, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38593255

RESUMO

PURPOSE: To investigate the effect of age on visual outcomes after the bilateral implantation of trifocal intraocular lenses (IOLs). METHODS: A total of 290 patients (580 eyes) who underwent bilateral implantation of a trifocal IOL were enrolled in this retrospective case-control study. Patients were divided into five age groups: 45 to 49, 50 to 54, 55 to 59, 60 to 64, and 65 years and older. Postoperative monocular uncorrected and corrected distance visual acuity (UDVA and CDVA, respectively), uncorrected near visual acuity (UNVA), binocular distance-corrected defocus curve, spectacle dependence for near and distance vision, and patient satisfaction scores were compared among the five groups. RESULTS: The 45 to 49 years group had significantly better mean UDVA (0.02 ± 0.05 logMAR) and UNVA (0.02 ± 0.04 logMAR) than the 65 years and older group (0.06 ± 0.09 and 0.09 ± 0.09 logMAR; P = .029 and P < .001; respectively). However, no significant differences were observed in the mean CDVA among the groups. Binocular visual performance of the 45 to 49 years group was better than that of the 65 years and older age group at defocuses of +1.00, +0.50, -1.00, and -3.00 D. No significant differences were observed in spectacle dependence for near and distance vision or in patient satisfaction scores among the five groups. CONCLUSIONS: Bilateral implantation of trifocal IOLs can provide excellent near and distance vision in both young and older patients. However, UDVA and UNVA revealed considerably worse results in the older group, although no significant difference was observed in CDVA and postoperative refractive errors by age. [J Refract Surg. 2024;40(4):e270-e277.].


Assuntos
Lentes Intraoculares , Facoemulsificação , Humanos , Idoso , Pessoa de Meia-Idade , Refração Ocular , Implante de Lente Intraocular , Óculos , Estudos Retrospectivos , Estudos de Casos e Controles , Visão Binocular , Satisfação do Paciente , Desenho de Prótese
8.
J Refract Surg ; 40(4): e253-e259, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38593262

RESUMO

PURPOSE: To compare simulated keratometry (SimK) and total corneal power (TCP) in keratoconic eyes, to determine whether the differences are systematic and predictable and to evaluate an adjusted TCP-based formula for intraocular lens (IOL) power calculation. METHODS: In a consecutive series of keratoconic eyes, measurements of SimK, TCP, posterior keratometry, and anterior and posterior corneal asphericities (Q-values) were retrospectively collected. The difference between SimK and TCP was linearly correlated to the biometric parameters. In a separate sample of keratoconic eyes that had undergone cataract surgery, IOL power was calculated with the Barrett Universal II, Hoffer QST, Holladay 1, Kane, and SRK/T formulas using the SimK and an adjusted TCP power. The respective prediction errors were calculated. RESULTS: A total of 382 keratoconic eyes (271 patients) were enrolled. An increasing overestimation of SimK by TCP was detected from stage I to III, with a significant correlation between the SimK and TCP difference and SimK in the whole sample (P < .0001, r2 = 0.1322). Approximately 7% of cases presented an underestimation of SimK by TCP. IOL power calculation with the adjusted TCP improved outcomes, achieving a maximum of 80% of eyes with a prediction error within ±0.50 diopters with the Hoffer QST, Holladay 1, and Kane formulas. CONCLUSIONS: Overall, SimK overestimated TCP. Such a difference could not be predicted by any variable. The proposed TCP-adjustment formula (TCPadj = TCP + 0.56 diopters) in keratoconic eyes for IOL power calculation might be valuable for improving refractive outcomes. [J Refract Surg. 2024;40(4):e253-e259.].


Assuntos
Ceratocone , Lentes Intraoculares , Facoemulsificação , Humanos , Ceratocone/diagnóstico , Implante de Lente Intraocular/métodos , Estudos Retrospectivos , Facoemulsificação/métodos , Óptica e Fotônica , Refração Ocular , Biometria/métodos
9.
Sci Rep ; 14(1): 8868, 2024 04 17.
Artigo em Inglês | MEDLINE | ID: mdl-38632326

RESUMO

A retrospective cohort study was conducted to observe the correction effect of Toric intraocular lens (IOL) implantation in cataract eyes with specific types of irregular corneal astigmatism. Thirty-four eyes with either the "asymmetric bow-tie" pattern (Type I) or the "angled bow-tie" pattern (Type II) were included. Corneal topography was assessed using Pentacam HR, and changes in preoperative corneal astigmatism, visual acuity, manifest refraction, and objective visual quality were measured and compared. The average uncorrected distance visual acuity improved significantly from 0.86 ± 0.40 logMAR to 0.22 ± 0.15 logMAR (P < 0.001). Preoperative corneal astigmatism of 2.05 ± 0.90 D was corrected to a postoperative residual astigmatism of 0.78 ± 0.57 D (P < 0.001), with 32% of eyes within 0.50 D. The residual astigmatism prediction errors in Type I and Type II cases were (0.97 ± 0.68 D) and (0.66 ± 0.37 D), respectively (P = 0.100). The mean spherical equivalent prediction error in Type II cases (0.07 ± 0.36 D) was significantly smaller than that in Type I cases (- 0.29 ± 0.52 D) (P = 0.030). This study concludes that Toric IOL implantation effectively corrects specific types of irregular corneal astigmatism in cataract surgery. Eyes with the "angled bow-tie" pattern show higher accuracy in refractive predictions compared to eyes with the "asymmetric bow-tie" pattern.


Assuntos
Astigmatismo , Catarata , Doenças da Córnea , Lentes Intraoculares , Facoemulsificação , Humanos , Astigmatismo/cirurgia , Implante de Lente Intraocular , Estudos Retrospectivos , Refração Ocular , Doenças da Córnea/cirurgia
10.
Turk J Ophthalmol ; 54(2): 63-68, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38644781

RESUMO

Objectives: To evaluate the clinical results of a new trifocal intraocular lens (IOL) with sinusoidal design by comparing with a traditional trifocal IOL. Materials and Methods: A total of 79 patients undergoing uneventful microincisional cataract surgery with bilateral implantation of one of two types of trifocal IOLs, the Acriva Trinova IOL (VSY) or Acrysof IQ PanOptix IOL (Alcon), were enrolled in this prospective study. Visual and refractive outcomes, contrast sensitivity (CS), and defocus curve were assessed at 3 months after surgery. Patient satisfaction and incidence of photic phenomena were also evaluated. Results: The number of patients/eyes were 48/96 in the Trinova group and 31/62 in the PanOptix group. There were no significant differences between the groups for monocular and binocular corrected/uncorrected distance or intermediate (at 60 cm) and near visual acuities (VA) postoperatively. The Trinova group had statistically significantly better intermediate VA at 80 cm than the PanOptix group (p<0.05). The CS results of both groups were within the normal limits. In the binocular defocus curve of both IOLs, we observed a peak of good VA at 0.0 diopters defocus and a useful wide range for intermediate distances. The incidence of photic phenomena in the Trinova group was lower at postoperative 1 month (p<0.05) but this difference disappeared at 3 months. A total of 47 patients (97.9%) in the Trinova group and 30 patients (96.7%) in the PanOptix group stated that they would recommend the same IOL. Conclusion: Both trifocal IOLs provide good visual quality outcomes and patient satisfaction.


Assuntos
Lentes Intraoculares Multifocais , Presbiopia , Desenho de Prótese , Refração Ocular , Acuidade Visual , Humanos , Estudos Prospectivos , Feminino , Masculino , Acuidade Visual/fisiologia , Idoso , Pessoa de Meia-Idade , Presbiopia/fisiopatologia , Presbiopia/cirurgia , Refração Ocular/fisiologia , Visão Binocular/fisiologia , Satisfação do Paciente , Sensibilidades de Contraste/fisiologia , Facoemulsificação , Seguimentos , Implante de Lente Intraocular/métodos , Lentes Intraoculares
11.
Arq Bras Oftalmol ; 87(4): e2022, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38656019

RESUMO

We present a case report detailing the successful phacoemulsification surgery with artificial iris implantation for two individuals with oculocutaneous albinism. These women suffered from cataracts, resulting in reduced visual acuity and heightened photophobia due to iris pigmentary epithelium deficiency. The patients underwent phacoemulsification along with prosthetic artificial iris implantation into the posterior chamber. This intervention resulted in improved visual acuity, reduced photophobia and glare, and an overall enhanced quality of life. Our report highlights two cases of successful phacoemulsification and artificial iris implantation in patients with oculocutaneous albinism and cataracts, leading to improved visual acuity, reduced photophobia, and enhanced quality of life. Notably, there are no prior records in South American literature of cataract surgery combined with artificial iris implantation for oculocutaneous albinism patients up to the time of this publication.


Assuntos
Albinismo Oculocutâneo , Iris , Facoemulsificação , Acuidade Visual , Humanos , Albinismo Oculocutâneo/cirurgia , Albinismo Oculocutâneo/complicações , Feminino , Iris/cirurgia , Facoemulsificação/métodos , Resultado do Tratamento , Catarata/complicações , Catarata/congênito , Qualidade de Vida , Adulto , Órgãos Artificiais , Implantação de Prótese/métodos , Pessoa de Meia-Idade , Fotofobia/cirurgia , Fotofobia/etiologia
12.
Arq Bras Oftalmol ; 87(4): e2023, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38656032

RESUMO

We present a case of a patient complaining of monocular diplopia due to a decentered ablation after LASIK. The patient underwent a wavefront-guided retreatment, which resulted in an epithelial ingrowth complication. Additionally, the patient developed cataract, with cataract surgery requiring reliable biometric measurements. Therefore, we opted for corneal treatment and corneal surface regularization. Although we attempted to lift the flap and wash the interface initially, the procedure proved unsuccessful, thereby necessitating immediate flap amputation. Once the corneal surface was regularized in the seventh postoperative month, transepithelial photorefractive keratectomy was successfully performed to homogenize the ocular surface, thereby significantly improving the patient's corrected visual acuity and resolving monocular diplopia. The surface and corneal curvature stabilized by the fifth month after the procedure. Phacoemulsification was then performed along with the implantation of a toric monofocal lens, which was selected using an appropriate formula, resulting in an excellent uncorrected visual acuity.


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Facoemulsificação , Retalhos Cirúrgicos , Acuidade Visual , Humanos , Facoemulsificação/efeitos adversos , Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Masculino , Diplopia/etiologia , Resultado do Tratamento , Topografia da Córnea , Catarata , Pessoa de Meia-Idade
13.
Int Ophthalmol ; 44(1): 194, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38656707

RESUMO

PURPOSE: To evaluate the magnitude of IOL transversal shift (ITS) after phacoemulsification and to analyse the factors contributing to IOL decentration and ITS. METHODS: 94 consecutive patients who underwent cataract surgery and IOL implantation was enrolled. Each patient underwent anterior segment optical coherence tomography with CASIA 2 (Tomey, Nagoya, Japan) to assess crystalline lens decentration, thickness and diameter seven days preoperatively and at one and sixty days postoperatively. Univariate and multivariate linear regression analysis were performed to evaluate the determinants of ITS and final decentration. RESULTS: The preoperative crystalline lens diameter was associated with the ITS and with the IOL final decentration. A positive association between the final IOL decentration and the first post-surgical day decentration was found (p < 0.0001). CONCLUSION: Greater crystalline lens diameter was associated with greater decentration and with greater ITS. Day-one IOL decentration seems to be the main determinant of final IOL decentration.


Assuntos
Segmento Anterior do Olho , Facoemulsificação , Tomografia de Coerência Óptica , Humanos , Facoemulsificação/efeitos adversos , Tomografia de Coerência Óptica/métodos , Masculino , Feminino , Idoso , Segmento Anterior do Olho/diagnóstico por imagem , Lentes Intraoculares/efeitos adversos , Pessoa de Meia-Idade , Acuidade Visual , Idoso de 80 Anos ou mais , Migração do Implante de Lente Intraocular/diagnóstico , Migração do Implante de Lente Intraocular/etiologia , Implante de Lente Intraocular/efeitos adversos , Complicações Pós-Operatórias/diagnóstico , Cristalino/diagnóstico por imagem , Estudos Prospectivos
14.
BMC Ophthalmol ; 24(1): 189, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38658894

RESUMO

PURPOSE: To evaluate short-term visual and refractive outcomes after implantation of a diffractive trifocal intraocular lens (IOL) in cataract patients with phacoemulsification (PHACO) and femtosecond laser assisted cataract surgery (FLACS). SETTING: Department of Ophthalmology, Shanghai Aier Eye Hospital, China. DESIGN: A retrospective, observational study. METHODS: Patients who underwent cataract surgery combined with Acrysoft IQ PanOptix trifocal IOL implantation were enrolled and divided into three groups: PHACO group, LAstig-FLACS group (astigmatism less then 1D) and HAstig-FLACS group (astigmatism more than 1D). Logarithm of the minimum angle of resolution (logMAR) visual acuity of uncorrected distance (UDVA), intermediate (UIVA), near visual (UNVA), defocus curve, surgically induced astigmatism (SIA) were evaluated in 1 months postoperatively and wavefront aberrations were evaluated in 6 months. RESULTS: 101 eyes of 60 patients were included with 31 eyes in PHACO group, 45 eyes in LAstig-FLACS group and 25 eyes in HAstig-FLACS group. Significant difference was found of internal Strehl Ratio (SR) between PHACO and LAstig-FLACS group (P = 0.026). In PHACO group, 79.31%, 86.21%, 72.41% of eyes gain visual acuity LogMAR 0.1 or more in UDVA, UIVA and UNVA, while 83.72%, 93.02%, 93.02% of those in LAstig-FLACS group and 92.00%, 84.00%, 76.00% in HAstig-FLACS group. CONCLUSIONS: Panoptix diffractive trifocal IOL provides satisfied visual outcome in no matter FLACS or PHACO. Besides, trifocal IOL implantation via FLACS can provide a better accumulative visual acuity outcome at all distance than PHACO in 1 month. Femtosecond laser assisted limbal relaxing incisions (FLLRIs) is an excellent way to reduce a patient's corneal astigmatism.


Assuntos
Terapia a Laser , Lentes Intraoculares Multifocais , Facoemulsificação , Refração Ocular , Acuidade Visual , Humanos , Estudos Retrospectivos , Masculino , Feminino , Facoemulsificação/métodos , Acuidade Visual/fisiologia , Pessoa de Meia-Idade , Terapia a Laser/métodos , Idoso , Refração Ocular/fisiologia , Implante de Lente Intraocular/métodos , Pseudofacia/fisiopatologia , Resultado do Tratamento , Desenho de Prótese , Extração de Catarata/métodos , Seguimentos
15.
J Cataract Refract Surg ; 50(5): 498-504, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38651697

RESUMO

PURPOSE: To compare 3 capsulotomy centration methods. SETTING: Private clinic, Zlin, Czech Republic. DESIGN: Prospective, consecutive case series. METHODS: 180 eyes undergoing cataract surgery had anterior capsule staining with microfiltered 0.4% trypan blue solution before selective laser capsulotomy. The first 60 eyes (Group 1) had mydriatic dilated pupil centered capsulotomies. The next 60 eyes (Group 2) were centered on the trypan blue central landmark (TCL). The final 60 capsulotomies (Group 3) were centered on the patient fixated coaxial Purkinje reflex (CPR). Measurements between key anatomical landmarks and the TCL, CPR capsulotomies, and implanted intraocular lens (IOL) center were made. RESULTS: The TCL, observed in >94% of eyes in the study, coincided with the CPR with a displacement of <0.1 ± 0.1 mm. Group 1 capsulotomies were noticeably decentered on the IOLs by 0.3 ± 0.2 mm. The Group 2 symmetrical IOL relationship was maintained with a decentration of 0.15 ± 0.1 mm. Group 3 had a similar decentration with the IOLs with 0.15 ± 0.1 mm. Verification with IOLMaster 700 data and CALLISTO Eye System showed that the CPR and the TCL were coincident with the measured visual axis. CONCLUSIONS: The clearly visible TCL served as an alternate landmark to the patient fixated CPR, and being on the anterior capsule was not sensitive to tilt. Further patient compliance was not required. Both were superior to dilated pupil centration, to achieve symmetric IOL coverage. This has application for both capsulotomies and capsulorhexes.


Assuntos
Capsulorrexe , Corantes , Facoemulsificação , Azul Tripano , Humanos , Capsulorrexe/métodos , Estudos Prospectivos , Idoso , Corantes/administração & dosagem , Implante de Lente Intraocular , Masculino , Feminino , Pessoa de Meia-Idade , Cápsula Anterior do Cristalino/cirurgia , Pontos de Referência Anatômicos , Cápsula do Cristalino/cirurgia , Idoso de 80 Anos ou mais
18.
Int Ophthalmol ; 44(1): 200, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38662305

RESUMO

PURPOSE: To analyse real-world outcomes in Asian eyes of iStent inject, a second-generation trabecular micro-bypass stent, combined with phacoemulsification. METHODS: This is a multi-centre, observational study of glaucomatous Asian eyes that have undergone iStent inject implantation combined with cataract surgery. Patient data were extracted from the Fight Glaucoma Blindness! Registry. Outcome measures included those of IOP reduction, glaucoma medication reduction, and adverse events including the need for secondary surgery. RESULTS: 123 eyes of 86 patients with a mean age of 68.4 ± 9.3 years underwent iStent inject implantation with phacoemulsification. At baseline, the mean ± SD preoperative intraocular pressure (IOP) was 16.0 ± 4.4 mmHg, and the mean preoperative number of topical glaucoma medications was 1.9 ± 1.4. At 12 months 30.8% of eyes demonstrated a reduction in IOP greater than 20%, the mean IOP reduction was 12.5% with an additional reduction of 0.7 glaucoma medications. 40% of eyes were using no medications at 12 months compared to 16.3% preoperatively. 8.2% of eyes required a subsequent procedure within the 12-month follow-up window. CONCLUSION: iStent inject implantation combined with phacoemulsification in Asian eyes showed a reduction of IOP and glaucoma medication use in a real-world clinical setting. The safety profile of the device is good with minimal adverse outcomes, however, a subset of patients required secondary procedures within the 12 month follow up.


Assuntos
Pressão Intraocular , Sistema de Registros , Humanos , Masculino , Feminino , Idoso , Pressão Intraocular/fisiologia , Pessoa de Meia-Idade , Implantes para Drenagem de Glaucoma , Austrália/epidemiologia , Acuidade Visual , Resultado do Tratamento , Glaucoma/cirurgia , Glaucoma/fisiopatologia , Glaucoma/etnologia , Glaucoma/complicações , Facoemulsificação/métodos , Seguimentos , Idoso de 80 Anos ou mais , Povo Asiático/etnologia , Catarata/complicações , Estudos Retrospectivos
19.
Sci Rep ; 14(1): 9020, 2024 04 19.
Artigo em Inglês | MEDLINE | ID: mdl-38641638

RESUMO

This study aimed to evaluate the changes in intraocular pressure (IOP) before and after femtosecond laser capsulorhexis and lens fragmentation for cataract surgery. We measured the IOP before, immediately, 30 min, and 1 h after the laser procedure in 47 eyes of 47 patients who underwent the femtosecond laser procedure. The mean IOP was 17.51 ± 3.28 mmHg, 30.23 ± 6.70 mmHg, 17.96 ± 3.75 mmHg, and 21.77 ± 5.88 mmHg before, immediately after, 30 min after, and 1 h after the laser procedure, respectively. The mean IOP significantly increased immediately (adjusted P < 0.001) and 1 h (adjusted P = 0.001) after the laser procedure compared with the pre-laser IOP. The mean IOP at 30 min after the laser procedure was significantly lower than that immediately after the procedure (adjusted P < 0.001). However, the IOP 1 h after the laser procedure became higher than that 30 min after the laser procedure. Additionally, the IOP 1 h after the laser procedure was positively correlated with the baseline IOP and negatively correlated with the axial length. In conclusion, this study demonstrated that cataract surgery should be commenced within 30 min after the femtosecond laser procedure to ensure a safe cataract surgery that reduces the risk of increased intraocular pressure.


Assuntos
Extração de Catarata , Catarata , Oftalmopatias , Terapia a Laser , Facoemulsificação , Humanos , Pressão Intraocular , Terapia a Laser/métodos , Extração de Catarata/métodos , Lasers
20.
J Pak Med Assoc ; 74(3): 450-455, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38591276

RESUMO

Objectives: To assess the visual improvement and mean residual astigmatism in patients who underwent cataract surgery with toric intraocular lens. METHODS: The retrospective, observational study was conducted at the Department of Ophthalmology, Aga Khan University Hospital, Karachi, and comprised data from January 1, 2018, to December 31, 2020, related to adult patients who had regular astigmatism of at least 0.75D and underwent cataract surgery with toric intraocular lens implantation using a digital marker. The patients were followed up on post-operative days 1, 7, 30, 90 and 180. Along with age, the degree of astigmatism was noted. The visual acuity was calculated pre- and post-operatively. The mean residual astigmatism was then noted for all patients post-operatively. Data was analysed using SPSS 22. RESULTS: The sample comprised 240 eyes of 177 patients; 99(55.9%) males and 78(44.1%) females. The mean age of the sample was 62.5±10.6 years. The mean unaided visual acuity improved post-operatively from 0.57±0.38 to 0.07±0.22 at 90 days. At the 30-day follow-up, mean residual astigmatism had reduced from 1.52±0.84 to 0.01±0.09 (p<0.001). The mean intraocular lens rotation from the intended axis was 0.73°±0.92° on day 30. CONCLUSIONS: Toric intraocular lens implantation using a digital marker could effectively reduce the post-operative cylinder, and improve the unaided visual acuity following cataract surgery.


Assuntos
Astigmatismo , Catarata , Lentes Intraoculares , Facoemulsificação , Masculino , Adulto , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Implante de Lente Intraocular , Astigmatismo/cirurgia , Estudos Retrospectivos , Catarata/complicações , Catarata/terapia , Refração Ocular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA